The Phase II PTG-1000 can perform two different methods of calculating thickness measurement by utilizing the charecteristics of both eddy current and magnetic induction
The Phase II PTG-1000 can perform two different methods of calculating thickness measurement by utilizing the charecteristics of both eddy current and magnetic induction. Both non-destructively and very accurately.
By attaching the appropriate probe (F-or N-type) you can detect either the thickness on nonmagnetic coating on a magnetic substrate or an insulating coating on a non-magnetic conductive substrate.
The PTG-1000 provides two operating modes: direct and application/batch (this mode stores both calibration seting and readings taken). The memory has a storage capacity for up to 3000 readings. Five different statistical parameters can be calculated, displayed and printed.
Using a special calibrating method the thickess of a chromic coating on a copper substrate can be measured. The PTG-1000 also provides a Calibration-through-coating (CTC) feature when only one coated substrates are available for measurement. Also by attaching a special CN200-probe, the thickness of non-magnetic conductive coating (copper, aluminum) on an insulating substrate (plastics, print boards) can be measured.
The Phase II PTG-1000 can be used in many areas of industry including manufacturing, general engineering, commercial inspection, etc.
|
Main Functions
|
|
- Ten types of probes are available to
cover a whole range of special measurement requirements: F-probes
(ferrous) and N-probes (non-ferrous)
- Four methods can be used o calibrate
the COATER
- Special feature: Calibration Through
Coating (CTG)
- Five different statistical
parameters can be calculated, displayed and printed
- Two measuring modes can be selected:
continuous and single
- Two operating modes ae provided:
direct and application/batch
- The memory has a storage capacity
for up to 3000 readings
- Histogram can be printed out for
further analysis for measured values
- Limits can be set, outside limit
warning will be given
- Automatic or manual switch off
- Easy deletions of wrong settings or
readings
- Retrieval and print out of stored
readings if desired
- Buzz prompts next step of operation
- Low battery indicator
- Errors during operation indicated by
buzzing and error codes on LCD
- Instrument can be used with or
without the integral/removable printer
|
|
Main Technical Data
|
- Measuring range with all possible
probes is 0-10.000 um max.
- Guaranteed tolerance: +- 1%H + 1 u m
(where H=nominal value)
- Min. substrate thickness: F1-probe
0.5mm/N1-probe 0.3mm
- Min. diameter of substrate: F1-probe
3mm/N1-probe 6mm
- Operating Temperature: 32-113 degrees
F (0-45 degrees C)
- Power source: 4 x 1.25V NiMH batteries
- Dimensions (LxWxH) 10.6 x 3.4 x 1.8 in
(270 x 86 x 47mm)
- Weight: 1.4 lbs (650g)
- The PTG-1000 comes complete with a
compact durable case, calibration plate and charger
|